+380674666055

Solveno RMX-ACO fan heater

Fan heaters are specially designed for poultry houses. To generate heat, it uses hot water from a boiler house or biogas cogeneration units.

 

Fan heaters are installed along the longitudinal walls of the poultry house, below the level of the fresh air valves. Due to high range of the air stream, fan heaters create a dense flow of warm air along the outer walls of the poultry house, which warm air is distributed circle-wise.

 

  • Heating power: 24-121 kW
  • Air consumption: 4.800-10.000 m3 / h
  • Range: 25-50 m
  • Weight without heat carrier: 41-88 kg

About

ADVANTAGESIMPLEMENTATION
Efficient gas combustion with low emissionDue to innovative combustion chamber the combustion process is as efficient as possible with a high degree of fuel combustion.
Exceptional reliability and durabilityComponents by the world's leading manufacturers are used:
- axial fan by ZIEHL-ABEGG (Germany);
- SIT gas valve (Italy);
- automatic controls by Siemens, Honeywell, SIT.
Resistant to aggressive environments inside the poultry houseThe case is made of stainless steel AISI 304, the burner is made of heat-resistant stainless steel AISI 310
Minimal personnel intervention in case of sudden
gas supply interruptions
Automation switches the air heater into standby mode, when gas supply is resumed, it automatically switches it on
Gas savingsDue to the run-down of the fan after the burner is switched off, residual heat is removed from the combustion chamber
High maintainability of the heat generator. Inexpensive replacement of elements in case of breakdownThe automation is based on individual electronic elements In case of failure, only the defective element shall be replacement, and not the entire panel
Washing the heat generator with a high pressure cleanrGas valve and automation are protected by IP65 sealed enclosures
Maximum protectionAutomation provides protection against:
- phase and neutral voltage drop;
- power line interference;
- overheating of the combustion chamber;
- drop in gas pressure;
Diagnostics of malfunctions and visual control of the combustion processSiemens combustion management system displays
- color indication of heat generator operating modes;
- error codes in case of femergency,
Read more about the different ways of heating poultry houses here

Specifications

CharacteristicsUnitRMX 33 ACORMX 63 ACORMX 93 ACO
Heater capacity troom=0С°, th=90/70С°кВт5890121
Heater capacity troom=20С°, th=80/60С° кВт365574
Heater capacity troom=35С°, th=80/60С° кВт243851
Airflowм3/ч4.8007.70010.000
heat exchanger characteristics
Number of heat exchanger rowsr333
Distance between lamellasmm4.24.24.2
Maximum heat carrier temperature130130130
Maximum working pressureMpa111
Pipeline connection diameterinch1"1¼"1¼"
Protection against aggressive environmentsepoxidized coating + protective paint layer
fancharacteristics
Electrical voltageV/hz400/50400/50400/50
Engine power consumption kW0.480.771
Engine protection classIPIP54IP54IP54
Jet length1 m252850
fan heater mounted
Size (LхHхD)mm750х750х607825х850х610975х960х620
Weight without heat carrierkg415288
Nozzle diametermm470520580
TemperatureRMX 33 ACORMX 63 ACORMX 93 ACO
Thermal output Q (kW) / Thermal jump ∆T (C °)
Тroom (C°)Тwater(C°)Q (kW)∆T (C°)Q (kW)∆T (C°)Q (kW)∆T (C°)
3590/7032.519.950.919.867.911.6
80/6024.214.838.314.950.814.7
75/552012.331.212.442.212.2
3390/703420.953.120.870.920.5
80/6025.715.840.615.95415.6
75/5521.513.234.313.445.413.2
3090/7036.222.456.522.275.522
80/602817.344.117.358.717.1
75/5523.814.737.814.950.214.7
2590/704024.962.124.683.224.3
80/6031.819.849.819.766.519.6
75/5527.717.243.617.358.117
2090/7043.727.367.726.990.826.7
80/6035.522.255.42274.221.8
75/5531.419.749.319.665.919.4
1790/7045.928.87128.395.328.1
80/6037.823.758.823.478.823.2
75/5533.721.152.720.970.520.8
090/7058.336.889.736120.935.9
80/6050.331.877.731.2104.531.1
75/5546.329.371.728.896.428.6

Accessories

шланги Flexible hoses. (for RMX-ACO and RMX-ACV models)

 

Stainless steel braided rubber hose
  • Diameters 1″and 1 1/4″
  • Length 1.5, 2, 2.5 and 3 meters
рамка Wall-mounted fixing bracket for RMX-ACO When mounted on brackets, the fan heater can be rotated in several positions:иях:
  1. OPERATING POSITION: the fan heater can rotate around its axis horizontally, which makes it possible to change the direction of the air flow in the poultry house;
  2. MAINTENANCE POSITION: the fan heater is placed along the wall to give way to special vehicles during sanitization of the poultry house after completion of the growing cycle, its mounting height does not change.
Тепловентилятор Solveno RMX-ACO фото 11 Fasteners and connections kit for horizontal RMX-ACO fan heaters with adjustable mounting height. the kit includes :
  1. Mounting frame;
  2. System of cables and suspensions;
  3. Manual winch;
  4. Flexible hoses for water supply (1.5m.p.) – 2 pcs.
  5. Ball valves – 2 pcs;
лебедка Manual winch for RMX-ACO and RMX-ACV

Video

Fan heater operation example

Downloads

Case study

Still have questions? Ask a specialist!

Fill in the following fields and our consultants will contact you. We will study your situation and find the best solution.